Product Description
DSH-10A Halogen Drying Method Moisture Moisture Analyzer
The supper high resolution back window matrix liquid crystal display (LCD),marking it easier to operate in the dark place, and the user will have more comfortable vision.
Feature:
1.The supper high resolution back window matrix liquid crystal display (LCD),marking it easier to operate in the dark place, and the user will have more comfortable vision.
2.Touch-tone chain plate makes the operation easier.
3.The high precision heat insulation type sensor makes temperature for data acquisition reliable.
4.The use of halide torch for heating and curing make worming more rapidly and test time shorter.
5.In the process of test ,the dry state can be directly confirmed to speculate the finish time.
6.It is equipped with automatic peeling function ,it can measure immediately and continuously, and also measure accurately through the zero drift correction.
7.Installed with RS232 interface inside, the products can be directly connected to computer and printers etc.
8.The halogen drying method moisture analyzer can test the free water content of chemical raw materials ,grain, mineral,plaster,biological product, food, paper,
pharmaceutical raw materials, textile raw materials and etc.
9.non-contact, continuous, real-time, automatic control, quick determination of moisture, accurate
Technical Data Sheet
SN. | Item | Parameter |
1 | Weighing range | 10g |
2 | Readability | 10mg(0.01g) |
3 | Repeatability(3g samples) | 0.5% |
4 | Minimum sample amount | 0.5 |
5 | Advised sample amount | 3-10g |
6 | Heat up time | 1-99minutes, 1 minutes interval |
7 | Temperature program | Standard |
8 | Terminal control | Timing, Automatic |
9 | Heating temperature range | 50-180 degrees |
10 | Showing content | Moisture%, Solid%, Weight, Time, Data, etc. |
11 | Pan size | 100mm |
12 | Overall dimension | 265*160*150 |
13 | Net weight | 5kg |
14 | Total weight | 6kg |
15 | Heating source | Halide torch |
Model | DSH-10A | DSH-50A-5 | DSH-50A-1 | DSH-50A-10 | DSH-100A-1 |
Weighing Range | 10g | 50g | 50g | 50g | 100g |
Readability | 10mg | 5mg | 1mg | 10mg | 1mg |
Repeatability(3g samples) | 0.50% | 0.30% | 0.20% | 0.50% | 0.30% |
Minimum Sample Amount | 0.5 | ||||
Advised Sample Amount | 3-10g | ||||
Heat up time | 1-99minutes,1 minutes interval | ||||
Temperature Program | Standard | ||||
Terminal Control | Timing, Automatic | ||||
Heating Temperature Range | 50-180 degrees | ||||
Showing Content | Moisture%, Solid%, Weight, Time, Data etc | ||||
Pan Size | 100mm | ||||
Dimension | 265x160x150 | ||||
Net Weight | 5kg | ||||
Heating Source | Halide Torch |